AV-1-08 | 1" and 2" Air Valve (PDF) | 0
|
BP-1-08 | Backflow Preventer, Reduced Pressure Assembly, 2" and Smaller Service (PDF) | 0 |
BP-2-08 | Backflow Preventer, Reduced Pressure Assembly, 3" and Larger Domestic Service (PDF) | 0 |
BP-3-08 | Backflow Preventer, Reduced Pressure Assembly, 3" and Larger Fire Service (PDF) | 0 |
CL-1-08 | Clearance Requirements for Water Mains from Other Utilities and Structures (PDF) | 0 |
CL-2-08 | Horizontal and Vertical Clearance Requirements between Water Mains and Sanitary Sewers (PDF) | 0 |
CL-3-08 | Horizontal and Vertical Clearance Requirements between Water Mains and Storm Drains (PDF) | 0 |
CL-4-08 | Clearance Requirements for Water Mains, Services and Other Facilities (PDF) | 0 |
CL-5-08 | Clearance Requirements for Meter, Vault and Other Facility Installations (PDF) | 0 |
ET-0-08 | Electrolysis Test Station General Notes (PDF) | 0 |
ET-1-08 | Electrolysis Test Station Bonding Wire and Test Lead Connections for Steel Pipe (PDF) | 0 |
ET-2-08 | Electrolysis Test Station Steel Pipe Calibration Span (PDF) | 0 |
ET-3-08 | Electrolysis Test Station Marker Post Installation Details Undeveloped Areas (PDF) | 0 |
ET-4-08 | Electrolysis Test Station Developed Areas (PDF) | 0 |
ET-5-08 | Electrolysis Test Station Steel Pipe Encasement Test Station (PDF) | 0 |
ET-6-08 | Electrolysis Test Station Insulating Joint Test Station, Non-insulating Joint Bonding and Flanged Joint Bonding on Steel Pipelines (PDF) | 0 |
ET-7-08 | Electrolysis Test Station Anode Connection (PDF) | 0 |
FH-1-08 | Fire Hydrants (PDF) | 0 |
FH-2-08 | Fire Hydrant Locations (PDF) | 0 |
JP-1-08 | New Main Jumper Piping (PDF) | 0 |
MP-1-08 | Marker Post and Curb Markings (PDF) | 0 |
S-1-08 | 1" Service Line for 3/4" and 1" Meters without Fire Sprinkler Connections (PDF) | 0 |
S-2-08 | 1-1/2" and 2" Service Lines, 1-1/2" and 2" Meters without Fire Sprinkler Connections (PDF) | 0 |
S-3-08 | 1" Service Line, 3/4" and 1" Meters without Fire Sprinkler Connections (PDF) | 0 |
S-4-08 | 1-1/2" Service Line and Meter in Dual Meter Box for Residences with Fire Sprinklers (PDF) | 0 |
S-5-08 | 1-1/2" Service Line and 1" Meter in Dual Meter Box for Residences with Fire Sprinklers (PDF) | 0 |
S-6-08 | 1-1/2" Service Line and 1" Meter in Single Meter Box for Residences with Fire Sprinklers (PDF) | 0 |
S-7-08 | 1" Service Line and Meter in Dual Meter Box for Residences with Fire Sprinklers (PDF) | 0 |
S-8-08 | 1" Service Line and Meter in Single Meter Box for Residences with Fire Sprinklers (PDF) | 0 |
S-9-08 | Typical Steel Service Lateral (PDF) | 0 |
S-10-08 | 2" Service Line and Detector Check Valve (PDF) | 0 |
S-11-08 | Address Labels and Markings for 1" through 2" Service Lines (PDF) | 0 |
SP-1-08 | Water Quality Sampling Pipe Assembly (Temporary - for Water System Construction) (PDF) | 0 |
TB-1-08 | Thrust Blocking for PVC Pipe Valve Clusters (PDF) | 1 |
TB-2-08 | Thrust Blocking for PVC Pipe Horizontal Fittings (PDF) | 0 |
TB-3-08 | Standard Blowoff for 6" and 8" PVC Mains (PDF) | 0 |
TB-4-08 | Standard Blowoff for 10" and 12" PVC Mains (PDF) | 0 |
TW-1-08 | Tracer Wire for Mains and Valves (PDF) | 0 |
TW-2-08 | Tracer Wire for Service Lines (PDF) | 0 |
V-1-08 | Line Butterfly Valve (PDF) | 0 |
V-2-08 | Line Gate Valve (PDF) | 0 |
VB-1-08 | Valve Box (PDF) | 0 |
WSP-1-08 | Steel Pipe Welded Joints (PDF) | 0 |
WSP-2-08 | Welded Steel Offset on PVC Pipe (PDF) | 0 |